libraw 0.20.0 returns incorrect D65 multipliers and rgb_cam for ERBG file

Hi,
I noticed that for the Sony F828 that has an ERBG sensor, the Daylight white balance multipliers returned by 0.20.0 is 2.094020 0.917032 1.222377 0.000000. However, on 0.19.5, the values are 2.094020 0.917032 1.222377 1.203671.

Similarly rgb_cam on 0.20.0 is
1.6726 -0.5983 -0.0743 0
0.0080 1.4036 -0.4116 0
0.0046 -0.4089 1.4043 0

but on 0.19.5 it is
1.6374 -0.2528 -0.0035 -0.3811
0.0672 0.8224 -0.5306 0.6410
-0.0009 -0.3551 1.4153 -0.0593

Is this expected?

Regards,
Dinesh